IES-2060 - 6 port lite managed switch
6x10/100Base-T(X) ports or 4x10/100Base-T(X) and 2x100BaseFX ports and wide operating temperature range from -40 to 70°C.
- Fastest Redundant Ethernet Ring: O-Ring (recovery time < 10ms over 250 units of connection)
- Open-Ring supports other vendor’s ring technology in open architecture
- O-Chain support the multiple redundant ring technology
- Multiple Redundant Ethernet technology RSTP/STP, O-Ring supported to protect your industrial network
- Provides Fast recovery technology for Ethernet multi-redundancy
- SNMP v1/v2c/v3 ,http server, telnet server support
- Supports LLDP protocol
- Configurable by Web-based and Windows utility (Open-Vision)
- Event notification through Syslog, Email, and SNMP trap
- Two 100Base-FX fiber ports support for long distance connection
- Rigid IP-30 housing design
- DIN-Rail and wall mounting enabled
| Physical Ports | |
| 10/100Base-T(X) Ports in RJ45 Auto MDI/MDIX | 6 |
| Technology | |
| Ethernet Standards |
IEEE 802.3 for 10Base-T |
| MAC Table | 1024 MAC addresses |
| Priority Queues | 4 |
| Processing | Store-and-Forward |
| Switch Properties |
Switching bandwidth : 1.2Gbps |
| Security Feature |
Enable/disable ports |
| Software Features |
STP/RSTP (IEEE 802.1D/w) |
| Network Redundancy |
O-Ring |
| LED Indicators | |
| Power Indicator | Green : Power LED x 3 |
| R.M. Indicator | Green : Indicates that the system is operating in O-Ring Master mode |
| O-Ring Indicator | Green : Indicates that the system is operating in O-Ring mode |
| Fault Indicator | Amber : Indicates unexpected events occurred |
| 10/100Base-T(X) RJ45 Port Indicator | Green for port Link/Act. Amber for Link |
| 100 Base-FX Fiber Port Indicator | Green for port Link/Act. Amber for Link |
| Fault Contact | |
| Relay | Relay output to carry capacity of 1A at 24VDC |
| Power | |
| Redundant Input Power | Triple DC inputs: 12 ~ 48 VDC on 7-pin terminal block, 12 ~ 45 VDC on power jack |
| Power Consumption (Typ.) | 5 Watts |
| Overload Current Protection | Present |
| Reverse Polarity Protection | Present on terminal block |
| Physical Characteristics | |
| Enclosure | IP-30 |
| Dimensions (W x D x H) | 54.2(W) x 106.1(D) x 145.4(H) mm (2.13x4.18x5.72 inch.) |
| Weight (g) | 657g |
| Environmental | |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Operating Temperature | -40 to 70°C (-40 to 158°F) |
| Operating Humidity | 5% to 95% Non-condensing |
| Regulatory Approvals | |
| EMI | FCC Part 15, CISPR (EN55022) class A |
| EMS | IEC61000-4-2 (ESD), IEC61000-4-3 (RS), IEC61000-4-4 (EFT), IEC61000-4-5 (Surge), IEC61000-4-6 (CS), IEC61000-4-8, IEC61000-4-11 |
| Shock | IEC60068-2-27 |
| Free Fall | IEC60068-2-32 |
| Vibration | IEC60068-2-6 |
| Safety | EN60950-1 |
| MTBF (Hours) (MIL-HDBK-217F2, GB, GC, 25°C ) | 383,478 |
| Warranty | 5 years |
/*= $storeName*/ ?>